|
TOP Server News and Announcements - 2005 (click for printable version
)
This page lists TOP Server updates and news announcements from 2005.
November 23, 2005
TOP Server Version 4.190.341 Released - (Download here) (More Information on Drivers)
- ServerMain.exe Updates (V4.190.341)
- Enhancements:
- Added new system tag "_NoError" to Channel.Device._System This value will be set to TRUE when the device is not in an error state and FALSE
when it is in an error state. This is the inverse of our _Error tag.
- Added tooltip support for the device ID setting found on the device property page. If the device ID exceeds the length at which it can be fully displayed, hovering over
the control will display the ID in a tooltip
- Fixed:
- Fixed event view painting issue when sorting the event list by Date/Time when Autoscroll was not selected.
- OPC Quick Client (V4.50.93)
- Enhancements:
- Added support for boolean arrays
- Added ability to set a default groupupdate rate for automatically generated projects. See Tools | Options.
- Added ability to browse remote machine/servers.
- Added remote machine name to the 'server view' server name if used by the server connection.
- Fixed:
- Fixed write dialog repainting issues when a write field edit box is selected and you use the mouse wheel to scroll the list.
- Fixed write dialog issue where the Apply button was not properly enabled when the delete key is pressed to modify a write value.
- Fixed write dialog repainting issues when a write field edit box is selected and you resize the column headers.
- Fixed issue with auto-generated projects that contain tag names that are maxed (or close to max) out in length.
- Moved all asynchronous refresh operations to the group menu level where they belong. They were previously at the item menu level.
- We now prevent the user from changing the group update notification if the group is connected to the server, since this is not allowed to be an on-the-fly change.
- Reworded browse dialog access rights values from Any/ReadOnly/WriteOnly/Read/Write to Any/Readable/WriteAble/R and/or W for clarity on what the server is returning in
accordance with the 2.05a specification
- Driver Updates
- Allen-Bradley DH+
- Updated float arrays to return 0 for any item that contains an invalid IEEE floating point value.
- Fixed driver load issues related to KTX and KT cards.
- Allen-Bradley Ethernet
- Updated float arrays to return 0 for any item that contains an invalid IEEE floating point value.
- Allen-Bradley ControlLogix
- Updated float arrays to return 0 for any item that contains an invalid IEEE floating point value.
- Added support for MicroLogix 1100 via Ethernet connection - Click for Product Page
- Changed default data type (selectable from device property) from Long to Float for new devices.
- Allen-Bradley DF1
- Updated float arrays to return 0 for any item that contains an invalid IEEE floating point value.
- Allen-Bradley Bulletin 900
- Added support for 2 new models: TC8 and TC16 with enhanced features
- Added support for DWord and Long data types to addresses that originally only supported the float data type.
- Automation Direct EBC
- Fixed an issue writing to Terminator I/O CTRIO discrete outputs DO32 and higher.
- GE Focas
- Fixed issue in the device wizard where you could potentially encounter an error Unsupported operation attempted when adding an unsolicited data area.
- GE Ethernet
- Fixed issue importing arrays of word-based memory types. The offset generated was 16 times the correct offset.
- Honeywell HC900 Ethernet
- Fixed device wizard exception that would occur upon canceling out of the wizard pages.
- Honeywell UDC Ethernet - New driver for the following devices:
- Honeywell UDC 2500
- Honeywell UDC 3200
- Honeywell UDC 3500
- Mitsubishi CNC Ethernet - New driver for the following device:
- Modbus ASCII Serial
- Added boolean array support.
- Added functionality to use Modbus function code 0x0F for single coil writes.
- Increased block size option for coils from 8-800 to 8-2000.
- Fixed issue with overriding the 'Use holding register bit mask writes' (function code 0x16) by function code 0x10 (when 'Use Modbus Function 0x06 for single
register writes' property is unchecked). What should happen is that when the function code 0x16 property is checked, this should take precedence and no matter what the selection for function code
0x06 or 0x10 for bit within word writes.
- Modbus Ethernet
- Added boolean array support.
- Added functionality to use Modbus function code 0x0F for single coil writes.
- Increased block size option for coils from 8-800 to 8-2000.
- Fixed issue with overriding the 'Use holding register bit mask writes' (function code 0x16) by function code 0x10 (when 'Use Modbus Function 0x06 for single
register writes' property is unchecked). What should happen is that when the function code 0x16 property is checked, this should take precedence and no matter what the selection for function code
0x06 or 0x10 for bit within word writes.
- Modbus Plus
- Added functionality to use Modbus function code 0x0F for single coil writes.
- Increased block size option for coils from 8-800 to 8-2000.
- Fixed issue with overriding the 'Use holding register bit mask writes' (function code 0x16) by function code 0x10 (when 'Use Modbus Function 0x06 for single
register writes' property is unchecked). What should happen is that when the function code 0x16 property is checked, this should take precedence and no matter what the selection for function code
0x06 or 0x10 for bit within word writes.
- Note: Boolean array was already present in this MB+ driver and is intentionally omitted when compared to other Modbus driver release notes
- Modbus Serial
- Added boolean array support.
- Added functionality to use Modbus function code 0x0F for single coil writes.
- Increased block size option for coils from 8-800 to 8-2000.
- Fixed issue with overriding the 'Use holding register bit mask writes' (function code 0x16) by function code 0x10 (when 'Use Modbus Function 0x06 for single
register writes' property is unchecked). What should happen is that when the function code 0x16 property is checked, this should take precedence and no matter what the selection for function code
0x06 or 0x10 for bit within word writes.
- Modbus Unsolicited Serial
- Added Boolean array support.
- Added ability for the user to set the upper limit of address range for all memory types, rather than limit it to 9999.
- Omron Fins Ethernet
- Fixed read issues related to the E register type for the CJ1 model.
- Fixed issues with float arrays.
- Omron Fins Serial
- Fixed read issues related to the E register type for the CJ1 model.
- Fixed issues with float arrays.
- Phillips P8 PC20
- Added BCD and LBCD support when using Addresses that specify integer data
- Siemens TCPIP
- Added support for Simatic Net Data Block Format Identifiers (subtype): X, B, W, CHAR, INT, DWORD, DINT and REAL (i.e. DB1,REAL0). X arrays are not supported.
- Changed the default type for certain Data Block subtypes: DBW and DW from Short to Word. Short is still valid. DBD and DD from Long to DWord. Long is still valid.
- Added LBCD support for suffix BCD used on DWords.
- Added support for 3rd party syntaxing. Syntax included for Simatic Net, INAT, Softing and Applicom. This feature makes it easier for users to switch to using the
TOP Server Siemens TCPIP driver as a replacement for other products.
- SIXNET UDR
- Fixed issue where the six32com.exe would fail to launch for us.
- Fixed issue where an exception could occur if a message is received for a slave device after that device has been deleted.
- UCON
- Added "Custom #7 (16-Bit)" check sum.
- Added variable length ASCII He1x Integer [hh hh .. ..] format.
- Added Serial Line Control Command which will allow user to set/clear RTS line and DTR manually.
- Fixed Event Counter out-of-bounds error issue which was resulting when the data start byte was set to a number greater than 1.
- Added support to ASCII int and ASCII real to handle spaces in between sign and numbers.
- Added negative direction Move Buffer Pointer command
- Added Test Bit within Byte command.
- Added Set Event Count command.
- Modified Mod Byte command to support modify bit writes on Scratch Buffer and Read Buffer commands.
- Yokogawa Controller Serial
- Fixed issues with Process, PID and OPRelated parameter tags for US1000
- Yokogawa MX
- Added Retransmission, InitBalance, and InitBalReset tags.
- Added scales and precision tags for channels that are AO/PWM.
- Included AO and PWM channels in counts for CH_High and CH_Low values.
- Yokogwaw YS Serial
- Fixed issues with communicating with more than 1 device on a channel.
August 11, 2005
TOP Server Version 4.180.338 Released - (Download here) (More Information on Drivers)
- New Driver Suites
- Siemens S5/S7 Suite
- combines S7-200/300/400 Ethernet, S7 Unsolicited Ethernet, S5 AS511/PG port serial, S5 3964/3964R, and S7-200 PPI drivers into a single orderable item
- Mitsubishi Suite
- combines Mitsubishi A and Q series serial and ethernet drivers with FX Serial and FX-Net serial drivers into a single orderable item.
- Simatic/TI Suite
- combines Siemens/TI 5x5 series NITP/TBP serial driver with Siemens/TI 5x5 series ethernet driver into a single orderable item.
- ServerMain.exe Updates (V4.180.338)
-Enhancements:
- Added the following application system tags: Date_Month, Date_Day, Date_Year4, Date_Year2, Time_Hour, Time_Hour24, Time_Minute, Time_Second, Time_PM. These tags break
up the components of the existing Date and Time system string tags, so that client applications are no longer required to parse the strings to obtain the individual elements.
- Last file Open and Save As paths are now shared rather than being separate. This makes it easier for users to Open up the last saved project
if it resides in a location that is different from the last opened project location.
- Added multi-line tool tip support for the event view. If the column that the mouse cursor is over contains text that can not be fully
displayed in the current view, a tool tip with all the data will be shown.
- Upon loading the server that utilizes a driver that has had its license expire, we will now periodically log an event message to indicate that the
license has expired when a client attempts to add items that references.
- Updated event log Copy/Paste contents to include the date and time with each TX/RX frame in the same format as the event log and OPC diagnostics.
This will assist with cross-referencing diagnostic information.
- Increased the number of drivers that are displayed when selecting the driver name drop-down list in the 'New Channel - Device Driver'
channel wizard page.
- Added event log message when the enabled state is modified on a device. On startup, a message for each device that is disabled is logged to
indicate the disabled state.
- Fixes
- Fixed issue with not being able to undo changes made on a channel (e.g., Name).
- Fixed alias dialog issue where the where the keyboard focus would be lost after deleting an alias (i.e., unable to use the tab control to move to
other controls on the dialog).
- Fixed alias mapping issue where the Map To string would always concatenate the newly selected path to the previously selected path.
- Fixed DA 3.0 compliancy issue when running on systems with multiple processors or hyper-threading enabled. Cloning a group with a requested
interface that is not supported by the group, could cause the server to not perform device reads on any item that referenced the same address (qualified ID) as an item belonging to the cloned group. The
result is that the server would always return failure for a device read request on these particular items for the lifetime of the client/server connection that performed the Clone Group request.
- Fixed DA 3.0 compliancy issue when running the server on a machine with multiple processors or hyper-threading enabled. Due to the nature of
the fix and how it would affect existing projects the user must enable this compliance fix under Tools | Options | OPC Compliance : "Return initial updates for items in a single callback".
When selected (compliant behavior) we will return all outstanding initial item updates in a single callback. When deselected (default behavior) we will return initial updates as they are available
which could result in multiple callbacks. Note: If the server was previously running with Full Compliancy selected, this will automatically be deselected so that the pre-existing behavior is maintained.
- Fixed potential application deadlock when viewing Channel Diagnostics and either Resetting or Pausing the view.
- Fixed unnecessary event log from being posted if you enable auto demotion and disable auto demotion, while not in a demoted state. The server
would log a message indicating the device was auto-promoted even though it was not demoted.
- Fixed event view painting issue when sorting the event list by Date/Time when Autoscroll was not selected.
- Intellution PDB Interface - Fixed issue that would cause integer data to sometimes be displayed in floating point format when using TX blocks.
Drivers
- AB Ethernet:
-Upon failing after x successive timeouts, the driver will close the communications socket to reduce the possibility of having
to synchronize with previously buffered requests.
- AutomationDirect EBC:
-NetEdit launch has been moved to General tab on Device Properties dialog.
- AutomationDirect ECOM:
-NetEdit launch has been moved to General tab on Device Properties dialog. -Fixed issue in which reading a block of
32-bit values (i.e. Float) could exceed the maximum number of bytes allowed by the device, resulting in a 'Device Not Responding' error. -Fixed write toggle issue when writing to Control Relays (C).
-Added array support for Data Words (V). Support includes Word, Short, BCD, DWord, Long, LBCD and Float arrays.
- Allen-Bradley DH+:
-Fixed ASCII (A File) issue where the last element of an array would always read NULL for arrays of even length size
starting at an odd byte offset.
- Allen-Bradley Ethernet:
-Fixed ASCII (A File) issue where the last element of an array would always read NULL for arrays of even length size
starting at an odd byte offset
- ControlLogix:
-Renamed model "ControlLogix 5550" to "ControlLogix 5500" to better represent the 5500 series of supported
ControlLogix CPUs. Previous and current support under this model include: 5550, 5553, 5555, 5561, 5562 and 5563. -Fixed Physical Blocking read issue for UDT's greater than 65535 bytes in size.
-Fixed issue that could cause an unnecessary "CIP connection timeout" when going from Symbolic Addressing Mode to a Physical Addressing Mode. -Average Device Turn-Around Time (ms) to Performance
Statistics. This will aid in gauging how long it takes on average for the PLC to respond to the request.
-Fixed bug that could cause unnecessary "CIP connection timeouts" during auto tag generation and/or project upload. -Added support for ENI:Micrologix Function Files: RTC, HSC, IOS, CS0 and CS1.
-Fixed ASCII (A File) issue where the last element of an array would always read NULL for arrays of even length size starting at an odd byte offset
- DF1:
-Fixed issue where a write of LEN bytes to an ASCII (A File) string of length LEN would write two NULL terminators to the bytes
following the string. -Added SLC 5/05 to Model selection. -Fixed Half-Duplex Master issue that would halt writes to a Slave if a previous Master Message write request was never received by the Slave.
Fixed ASCII (A File) issue where the last element of an array would always read NULL for arrays of even length size starting at an odd byte offset
- Krauss Maffie:
-Addition of the following new element types: CYCCNT, CAVSET, CAVCNT, ALARM.
- K-Sequence:
-Added Bit within Word Support for the V Registers.
- Mitsubishi Ethernet:
-Increased maximum number of channels from 100 to 256 -Added ability to synchronize the device time with the PC time
where the OPC server is running at a specific interval. This feature is configured under device properties.
- Modbus Ethernet:
-Added support for an Inter-request delay.
-Added unsolicited support for function code 08, sub function code 00 support (AKA Loopback). -Added unsolicited support for the following 3 data encoding options: Modbus byte order, First word low in 32 bit
data types and First Dword low in 64 bit data types. -Fixed issue where the "First Dword low in 64-bit data types" checkbox was not honored when reading/writing to tags of type double.
-Added support for multiple slave devices. -Wonderware users who need to make Tag databases changes in Excel should contact us about a new feature that can handle Output registers without the leading zero.
- Modbus Unsolicited:
-Fixed issue where writing to a string that overlaps another string(s) nearby caused junk characters to appear in the
overlapping string.
- Modbus Serial:
-Device Id range modified to allow 248 to 254
- Modbus Plus:
-Wonderware users who need to make Tag databases changes in Excel should contact us about a new feature that can handle Output
registers without the leading zero.
- NWL PCAMS:
-New driver for connectivity to NWL PCAMSNT (Precipitator Control and Management System for Windows NT)
- Omron Fins Ethernet:
-Fixed E registers read issue for the CJ1 model devices. This issue was discovered during Omron Toolbus testing
which was inherited from the Omron suite.
- Omron Fins Serial:
-Fixed E registers read issue for the CJ1 model devices. This issue was discovered during Omron Toolbus testing
which was inherited from the Omron suite.
- Optilogic:
-Added delay between reading the base definition and performing reads/writes to allow the base to complete the initialization
sequence on power-cycles and cable reconnects. The delay prevents the possibility of the base locking up. -Tags are no longer deactivated if an address is out of range or specified slot doesn't
exist. Therefore, if they ever become available the user will not have to restart the driver/server to obtain the data.
- Siemens S7-200:
-Added transaction id to read/write frames to facilitate packet synchronization over noisy networks resulting in
duplicated/resent packets.
- Siemens MPI:
-Added Array Support for Byte, Char, Word, Short, DWORD, Long, Float and LBCD data types.
- UCON:
-Added "Custom #6 (8-Bit)" check sum -Added "BYTE from 2 ASCII Hex chars (LC) [hh]" format
-Added "WORD from 4 ASCII Hex chars (LC BS) [hh hh]" format -Added "ASCII coded IEEE float (LC Rev) [hh hh hh hh]" format.
- Yokogawa Green Series Controllers Serial:
-New driver for this release - click for details
May 20, 2005
TOP Server Version 4.170.328 Released - (Download here) (More Information on Drivers)
- ServerMain.exe Updates (V4.170.328)
-Enhancements:
- Full OPC Data Access 3.0 Support. 100% Compliance Test Success and Tested at the 2005 North American Interoperability
Workshop in Tampa (4/25-4/29)
- Ability to access Tag Properties as OPC Data Access Items (e.g., Channel.Device.Tag._Description,
Channel.Device.Tag._ClientAccess, etc…)
- Opened up the Channel, Device, Tag Group, Tag (etc.) naming convention to allow for non-alphanumeric characters other than
the underscore. The only limitations will be the period (a special delimiter used by the server) and using an underscore as the first character in a name (a special naming convention indicating that the
object is an internal/system object).
- Added the ability to save the event log contents to a text file.
- Added the ability to select or clear all OPC diagnostics filters with the click of a button.
- Added [Topic Name] to Wonderware specific add item failure event messages.
- Added demo expiration time left to the application's title bar (if in demo mode).
- Fixed:
- Fixed issue with synchronous device reads blocking for a lengthy amount of time if a device has data collection disabled.
- Fixed issue with asynchronous device reads never returning an appropriate callback if a device has data collection disabled.
- Fixed item browse issue with leaves (tags) with the same name as their parent branch (device or tag group).
- Fixed default serial communications settings for a channel when modifying the selected driver for the channel. This only
occurred in wizard mode and only if the serial communications page was activated and then the back button was pressed to modify the selected driver.
- Fixed the appropriate clamping of the scan rate to 99999990 milliseconds upon importing a value larger than 99999990 via CSV
import.
- Fixed driver library initial update behavior for tags with slow update rates (e.g., If a tag was scanned at 10 seconds, it
could take up to 20 seconds (always a factor of 2) to send the client the initial update).
- Fixed driver library performance issue when placing a device in simulation mode with large tag counts.
- NIO Toolkit -iFix
- Corrected issues associated with data availability on IDS/IGS driver startup. - Added latched data support.
- New! - Triconix TSAA Ethernet Driver (V4.00.6)
- New driver supports:
- Tricon and Trident Controllers
- Redundancy NCM modules and Redundant NICs in the PC
- Import tag configuration from TriStation 1131 XML
- Modbus Aliases
- System tags indicate to client application the currently active network connection
- Multiple controllers per network supported
- Supports following bins for data access:
- Read/Write: 00, 01, 10, 11, 12
- Read Only (limited by controller): 02, 03, 04, 05, 06, 07, 08, 09
- Various data types supported for each bin, including the native data type in the PLC, plus driver supports bit access within words and floats for applications where
boolean data is packed.
- BACnet (V4.20.14)
- Fixed issue where memory exception would occur if automatic tag database generation is configured to happen on startup. - Added default tag set
generation for devices that do not support the read property multiple service or the "All" property.
- Automation Direct EBC (V4.70.72)
- Fixed data length issue for ReadModuleStatus that affects communications to T1H-EBC100 resulting in "Device not
responding" errors. - Fixed the handling of T1F-14THM and T1F-16RTD broken transmitter errors to prevent spurious error conditions. Works in conjunction with TIO firmware version 4.0.xxxx.
- Added support for P6.30 to model GS1, GS2 and GS3 Drives - Added support for P9.39 to model GS1, GS2 and GS3 Drives
- Automation Direct ECOM (V4.63.69)
- Fixed write toggle issue when writing to Control Relays (C).
- Hilscher Universal (V4.01.23)
- Added event log message for Boards that failed to initialize.
- Mitsubishi Ethernet (V4.70.45)
- Changed model name from "Mitsubishi Ethernet" to "A Series", and "Mitsubishi Q Series Ethernet" to
"Q Series". - Device ID hint now specific to model selection. - Added UDP support. - Added string support for W Link Registers. - Corrected backward compatibility issue with Q Series Device ID
format. Network number field is now optional. Local network, 0, is assumed if omitted.
- Omron Fins Ethernet (V4.50.41)
- Expanded source and destination node range to 254. - Expanded range of H registers for CS1 model to 1535. - Added CJ1 model.
- Omron Fins Serial (V4.41.38)
- Expanded destination node range to 254. - Expanded range of H registers for CS1 model to 1535.
- Siemens TCP/IP 200/300/400 Ethernet (V4.30.40)
- Added Inter-Request Delay Support - Fix performance issue for blocks of different scan rates. - Tags are no
longer deactivated when device responds with an error code. Instead such tags will be invalidated and retried on the next scan. - Added STRING support for Data Blocks.
- Fixed issue handling mass writes. Observed with synchronous i/o transactions.
March 15, 2005
TOP Server Version 4.160.317 Released - (Download here) (More Information on Drivers)
- USB key drives now supported for license transfer between PCs
- New! - BacNet Ethernet Driver (V4.10.11)
- Connect to Building Automation Systems via BacNet protocol over Ethernet
- Variety of object types and BacNet services supported
- Automatic Tag Database Generation
- Click for full details and pricing
- New! - Yokogawa YS100 Serial Driver (V4.01.15)
- Siemens Ethernet Driver (V4.23.33)
- Fixed issue handling mass writes. Observed with synchronous I/O transactions.
- Users of older verions are recommended to install the free upgrade
February 11, 2005
TOP Server Version 4.160.316 Released - (Download here) (More Information on Drivers)
- ServerMain.exe Updates (V4.160.316)
- Added support for auto-demotion to most drivers.
- New! - Advanced Simulator Driver (V4.00.03)
- This driver lets you setup in an ODBC compliant database a stream of values that you want to have written to OPC items in the driver, and the driver will "play" those items
through the OPC items.
- The driver simulates live data by traversing through all the records in the selected user table at a rate set by the user.
- The driver can stop after one playing of the records or loop around and repeat the records again.
- You can manually move to a specified record by writing to a "MoveTo" internal tag.
- Click for full details and pricing
- Allen-Bradley DH+/DH-485 Driver(V4.01.17)
- Fixed issue with multiple PKTXD cards.
- Added support for accessing Channel 2 of a PKTXD card.
- Added device property (PKTXD Channel ID) to determine which channel to use on a PKTX card.
- Allen-Bradley ControlLogix Driver(V4.80.122)
- Fixed ENI connection issue where upon Ethernet cable disconnection/reconnection, timeouts would occur indefinitely trying to synchronize expected responses with actual
responses.
- Fixed ENI connection issue where upon model change from an ENI model that uses connected messaging (ie ENI: ControlLogix) to one that used unconnected messaging (ie ENI:
Micrologix).
- Fixed buffer overrun issue encountered when driver receives erroneous data or portions of a data packet. May occur on noisy networks such as those involving radio modems.
- Fixed handling of Encapsulation Error 0x03 which occurs on ENI models if 24 seconds of idle time elapses between requests. Prior to this fix, affected tags would simply be
assigned bad quality. With this fix, the error will be handled and tags re-requested.
- Fixed handling of Register Session failure. The same socket would be used in subsequent attempts, requiring a restart of the server or break in connection.
- AutomationDirect EBC (V4.70.69)
- Changed data type for P2.01(Slip Compensation) to FLOAT. WORD operation remains unaffected for GS1/GS2/GS3 Drives.
- Added support for Status tags for Terminator I/O modules. Only Extended Error information is currently supported. Extended Error is commonly returned from Analog modules
with a broken transmitter (i.e. 14THM). This information is posted to the Event Log and now is available from a tag.
- AutomationDirect ECOM (V4.62.67)
- Fixed packet synchronization issues found when communicating over a wireless network.
GE Ethernet (V4.74.56)
- Corrected issue where value would "flicker" after a write in some client applications.
- Hilscher Universal (V4.00.21)
- Added support for DeviceNet Slave and Profibus DP Slave.
- Mitsubishi Ethernet (MELSEC) (V4.60.39
- Q series only: Added Net number to device ID/network address.
- Expanded Q Series Address Range for the following:
- X -> 0x3FFF
- Y -> 0x3FFF
- M -> 16383
- L -> 16383
- B -> 0x3FFF
- W -> 0x3FFF
- S -> 16383
- DX -> 0x3FFF
- DY -> 0x3FFF
- Modbus ASCII (V4.60.40)
- Addition of the following new features:
- Auto Tag Database Generation
- Double Data Type Support
- First Dword low in 64 bit data types
- Use default Modbus byte order
- Use holding register bit mask writes
- Use Modbus function 06 for single register writes
- Use Modicon bit ordering
- Use zero based bit addressing within registers
- Variable import file
- Write Only Access
- Modbus Serial (V4.121.97)
- Addition of the following new features:
- Modicon Bit Ordering
- 0/1-Based Bit Addressing
- Double Data Type Support for Modbus Model
- First Dword low in 64 bit data types
- Use holding register bit mask writes
- Omron Fins Ethernet (V4.30.39)
- Added support for Signed BCD/LBCD. Append 'D' to any Short/Long and that Short/Long will be treated as a Signed BCD/LBCD.
- Omron Fins Serial (V4.30.35)
- Added support for Signed BCD/LBCD. Append 'D' to any Short/Long and that Short/Long will be treated as a Signed BCD/LBCD. Append 'D' to any Word/DWord for
Unsigned BCD/LBCD support (same behavior as data types BCD and LBCD). Sign is stored in the Most Significant Bit.
- Siemens TCP/IP 200/300/400 Ethernet (V4.22.32)
- Fixed connection issues encountered with WinLC upon cable disconnect/reconnect.
- Simatic 505 Ethernet (V4.60.63)
- Added bit support for System Status Word (STW).
- Tiway Host Adapter (V4.46.61)
- Fixed issues with Network Manager Channel A & B and HIU configuration when "Use hardware default settings" and "Use dipswitch settings" are
un-checked.
- Fixed issue that would occur when cancelling the Channel wizard.
- User-Configurable Driver (U-CON) (V4.60.81)
- - Added support for inter-request delay.
- - Added support for device auto-demotion
- Uni-Telway (V4.21.49)
- Added string support to MW memory type.
- Added support for PL7-3 counters and timers and IEC 1131-3 timers using TSX Micro/Premium series PLC's.
- Yokogawa CX (V4.02.18)
- Increased buffer for response to accomodate increased string length of math expression parameter in new hyperstretch firmware.
- Yokogawa DX Ethernet (V4.49.53)
- Added support for DX200-S123
- Expanded Input Channels (CH101 - CH270)
- Added autogeneration of CHE.High and CHE.Low
- Eliminated autogeneration of skipped expandable input channels
- Yokogawa MX (V4.01.18)
- Added user selection of Special Data Handling (-INF / +INF, -99999/+99999).
Click Here for Prior Years News Updates
|